Merge pull request 'Added self-managed time control to a3pool.yaml' (#1) from test_time into main

Reviewed-on: #1
This commit is contained in:
Nicolas Bachschwell 2022-07-12 12:14:39 +00:00
commit 089a0fe069
2 changed files with 103 additions and 0 deletions

View File

@ -17,6 +17,10 @@ This is a standard config for the a3pool. Nothing special by far with 2 temp sen
The temperature sensors have the `pool_temperature` and `solar_temperature` and will show report the pool temperature and solar temperature respectively every 10 seconds. The temperature sensors have the `pool_temperature` and `solar_temperature` and will show report the pool temperature and solar temperature respectively every 10 seconds.
There is also one switch that is designed to turn the pump on and off. This works by giving an 500ms long impulse that should turn the pump on/off and sensing on a GPIO ping whenever the pump is currently on/off. This switch carries the name of `pump`. I know HOW CREATIVE... There is also one switch that is designed to turn the pump on and off. This works by giving an 500ms long impulse that should turn the pump on/off and sensing on a GPIO ping whenever the pump is currently on/off. This switch carries the name of `pump`. I know HOW CREATIVE...
It also has the possibility of having it's own clock.
Simply adjust the time using the `start_h`, `start_m` as well as `end_h`, `end_m` and enable the `control` switch to ensure the automatic control in on. The button `sync_to_clock`is used to sync the system back to the clock without having to know/care about on/off times, simply press the button and it should switch to on/off if it should be on/off respectively.
**HOWEVER: If the pump is set to off or to the physical clock with physical switch in the garage this will not work!** It will still report it's state correclty however. **HOWEVER: If the pump is set to off or to the physical clock with physical switch in the garage this will not work!** It will still report it's state correclty however.
There is an other switch that does not have any functionality yet but it's `automate_control` if anyone wants to know. There is an other switch that does not have any functionality yet but it's `automate_control` if anyone wants to know.

View File

@ -32,6 +32,81 @@ binary_sensor:
pullup: true pullup: true
id: pump_state id: pump_state
number:
- platform: template
name: "Start Hour"
id: start_h
optimistic: true
min_value: 0
max_value: 23
restore_value: true
initial_value: 8
mode: box
step: 1
- platform: template
name: "Start Minute"
id: start_m
optimistic: true
min_value: 0
max_value: 59
initial_value: 0
restore_value: true
mode: box
step: 1
- platform: template
name: "End Hour"
id: end_h
optimistic: true
min_value: 0
max_value: 23
restore_value: true
initial_value: 20
mode: box
step: 1
- platform: template
name: "End Minute"
id: end_m
optimistic: true
min_value: 0
max_value: 59
restore_value: true
initial_value: 0
mode: box
step: 1
button:
- platform: template
name: "Sync To Clock"
on_press:
then:
- lambda: |-
int startMins = (int) (id(start_h).state * 60) + id(start_m).state;
int endMins = (int) (id(end_h).state * 60) + id(end_m).state;
int nowMins = (id(a3poolTime).now().hour * 60) + id(a3poolTime).now().minute;
if(!id(control).state){
// Make sure wierd error or whatever
return;
}
if(startMins < endMins){
if(startMins < nowMins && nowMins < endMins){
id(pump).turn_on();
}
else{
id(pump).turn_off();
}
}
else if(startMins > endMins){
if(endMins < nowMins && nowMins < startMins){
id(pump).turn_off();
}
else{
id(pump).turn_on();
}
}
switch: switch:
- platform: gpio - platform: gpio
pin: 5 pin: 5
@ -41,12 +116,14 @@ switch:
- switch.turn_off: relay - switch.turn_off: relay
- platform: template - platform: template
name: "Automate Control" name: "Automate Control"
id: control
optimistic: true optimistic: true
restore_state: true restore_state: true
- platform: template - platform: template
optimistic: false optimistic: false
name: pump name: pump
id: pump
lambda: |- lambda: |-
if (id(pump_state).state) { if (id(pump_state).state) {
return true; return true;
@ -70,6 +147,28 @@ switch:
- delay: 500ms - delay: 500ms
- switch.turn_off: relay - switch.turn_off: relay
time:
timezone: "Europe/Vienna"
id: a3poolTime
platform: sntp
on_time:
- seconds: 0
months: 4-10
then:
- if:
condition:
lambda: 'return id(a3poolTime).now().hour == (int) id(start_h).state && id(a3poolTime).now().minute == (int) id(start_m).state && id(control).state;'
then:
- switch.turn_on: pump
- seconds: 0
months: 4-10
then:
- if:
condition:
lambda: 'return id(a3poolTime).now().hour == (int) id(end_h).state && id(a3poolTime).now().minute == (int) id(end_m).state && id(control).state;'
then:
- switch.turn_off: pump
dallas: dallas:
- pin: D4 - pin: D4
update_interval: 10s update_interval: 10s