Fixed a bug for chlorPump.yaml where the target would not properly load on start
This commit is contained in:
parent
1bd3b7eb90
commit
d21229fa73
@ -6,7 +6,10 @@ esphome:
|
||||
on_boot:
|
||||
priority: 600
|
||||
then:
|
||||
output.turn_on: wifi_status_led
|
||||
- output.turn_on: wifi_status_led
|
||||
- chlorine_pump.set_target:
|
||||
target: !lambda return id(chlorine_target).state;
|
||||
|
||||
|
||||
esp8266:
|
||||
board: nodemcuv2
|
||||
@ -175,19 +178,15 @@ sensor:
|
||||
- 47608 -> 0
|
||||
- 590566 -> 100
|
||||
unit_of_measurement: "%"
|
||||
- platform: template
|
||||
name: debug_last_raw_value
|
||||
id: debug_last_raw_value
|
||||
accuracy_decimals: 0
|
||||
unit_of_measurement: "points"
|
||||
|
||||
chlorine_pump:
|
||||
pump: pump_switch
|
||||
sensor: chlorine_sensor
|
||||
id: chlorine_pump_component
|
||||
target: 600
|
||||
disable_clock: false
|
||||
proportional_band: 400
|
||||
proportional_band: 200
|
||||
target: 650
|
||||
# get_target: !lambda return id(chlorine_target).state;
|
||||
on_pump_value:
|
||||
- lambda: |-
|
||||
if(pState != id(last_pump_state)){
|
||||
|
@ -21,6 +21,7 @@ CONF_PUMP_VALUE = "on_pump_value"
|
||||
CONF_CYCLE_START = "on_cycle_start"
|
||||
CONF_DISABLE_CLOCK="disable_clock"
|
||||
CONF_TARGET="target"
|
||||
CONF_TARGET_LAMBDA="get_target"
|
||||
CONF_PUMP_TIME_DIVIDER = "pump_time_divider"
|
||||
|
||||
def to_proportional_band(value):
|
||||
@ -44,15 +45,22 @@ StopAction = chlorine_pump_ns.class_("ChlorineStop", automation.Action)
|
||||
SetTargetAction = chlorine_pump_ns.class_("ChlorineSetTarget", automation.Action)
|
||||
ManualDoseAction = chlorine_pump_ns.class_("ChlorineDose", automation.Action)
|
||||
|
||||
CONFIG_SCHEMA = cv.COMPONENT_SCHEMA.extend({
|
||||
def validate_config(config):
|
||||
if (config.get(CONF_TARGET_LAMBDA, None) is not None) is not (config.get(CONF_TARGET, None) not in config):
|
||||
raise cv.Invalid("Either a fixed target or an get_target lambda must be set to get a target")
|
||||
return config
|
||||
|
||||
CONFIG_SCHEMA = cv.All(
|
||||
cv.COMPONENT_SCHEMA.extend({
|
||||
cv.GenerateID(): cv.declare_id(ChlorinePump),
|
||||
cv.Required(CONF_PUMP_OUT): cv.use_id(output.BinaryOutput),
|
||||
cv.Optional(CONF_SENSOR): cv.use_id(sensor.Sensor),
|
||||
cv.Optional(CONF_PUMP_CYCLE_TIME, default=360): cv.int_range(min=30, max=1400),
|
||||
cv.Optional(CONF_PUMP_PROPORTIONAL_BAND, default=200): to_proportional_band,
|
||||
cv.Optional(CONF_DISABLE_CLOCK, default=False): cv.boolean,
|
||||
cv.Optional(CONF_TARGET, 700): cv.int_range(300, 1400),
|
||||
cv.Optional(CONF_TARGET): cv.int_range(300, 1400),
|
||||
cv.Optional(CONF_PUMP_TIME_DIVIDER, 2): cv.float_range(1, 5),
|
||||
cv.Optional(CONF_TARGET_LAMBDA, 2): cv.templatable(cv.float_),
|
||||
cv.Optional(CONF_PUMP_VALUE): automation.validate_automation({
|
||||
cv.GenerateID(CONF_TRIGGER_ID): cv.declare_id(ChlorSensorOutputTrigger),
|
||||
}
|
||||
@ -61,7 +69,9 @@ CONFIG_SCHEMA = cv.COMPONENT_SCHEMA.extend({
|
||||
cv.GenerateID(CONF_TRIGGER_ID): cv.declare_id(ChlorSensorCycleTrigger),
|
||||
}
|
||||
),
|
||||
})
|
||||
}),
|
||||
validate_config
|
||||
)
|
||||
|
||||
|
||||
|
||||
@ -123,6 +133,11 @@ async def to_code(config):
|
||||
cg.add(var.set_prop_band(config[CONF_PUMP_PROPORTIONAL_BAND]))
|
||||
|
||||
#cg.add(var.set_state(config[CONF_STATE]))
|
||||
if CONF_TARGET not in config:
|
||||
template_ = await cg.templatable(config[CONF_TARGET_LAMBDA], [], float)
|
||||
cg.add(var.set_target_lambda(template_))
|
||||
else:
|
||||
cg.add(var.set_target(config[CONF_TARGET]))
|
||||
|
||||
|
||||
if CONF_PUMP_VALUE in config:
|
||||
|
@ -22,8 +22,9 @@ class ChlorinePump : public Component {
|
||||
CallbackManager<void(int, int)> callback_cycle_;
|
||||
int tOn = 0;
|
||||
int tOff = 0;
|
||||
float target_ = 700.0f;
|
||||
float target_ = -1;
|
||||
float tOn_divider_;
|
||||
std::function<float()> target_lambda_ = nullptr;
|
||||
|
||||
public:
|
||||
|
||||
@ -62,6 +63,11 @@ class ChlorinePump : public Component {
|
||||
});
|
||||
}
|
||||
}
|
||||
|
||||
void set_target_lambda(std::function<float()> callback){
|
||||
target_lambda_ = std::move(callback);
|
||||
}
|
||||
|
||||
void prime() {
|
||||
tOn = 30;
|
||||
tOff = 2;
|
||||
@ -81,6 +87,7 @@ class ChlorinePump : public Component {
|
||||
}
|
||||
|
||||
|
||||
|
||||
void setMillisPrecies(unsigned long waitPeriod){
|
||||
|
||||
if(last_action + waitPeriod + waitPeriod > millis()){
|
||||
@ -94,9 +101,17 @@ class ChlorinePump : public Component {
|
||||
|
||||
int calculatePumpTimeSeconds(float last_mesurement){
|
||||
|
||||
if(last_mesurement >= target_) return 0;
|
||||
float used_target = -1;
|
||||
if(target_ != -1){
|
||||
used_target = target_;
|
||||
}
|
||||
else{
|
||||
used_target = target_lambda_();
|
||||
}
|
||||
|
||||
float currentVal = target_ - last_mesurement;
|
||||
if(last_mesurement >= used_target) return 0;
|
||||
|
||||
float currentVal = used_target - last_mesurement;
|
||||
float proportionalValue = (currentVal / (float) prop_band);
|
||||
float timeInSeconds = proportionalValue * (float) cycle_time;
|
||||
|
||||
@ -154,6 +169,10 @@ class ChlorinePump : public Component {
|
||||
setMillisPrecies(1000);
|
||||
}
|
||||
}
|
||||
|
||||
void dump_config() override {
|
||||
|
||||
}
|
||||
};
|
||||
|
||||
class ChlorSensorOutputTrigger : public Trigger<bool, int> {
|
||||
|
Loading…
Reference in New Issue
Block a user